+55 (47) 3349-6168 kevenoll@kevenoll.com.br

PRODUCTS

TOP NUGARD

Product Description

 

Latex Glove with Powder for General Non-Surgical Use

Sizes: PP / P / M / G

Latex gloves for general non-medical use – TOP NUGARD brand, are used for use in food, aesthetics, domestic work, cleaning and maintenance industries, where there is no need for a sterile glove.

Made of 100% natural latex, non-medical, with bioabsorbable powder, ambidextrous and with a smooth surface. Disposable.

Glove for non-medical or surgical use, non-sterile, made of natural latex, ambidextrous, lightly lubricated with non-toxic bioabsorbable powder.
Composition: 100% natural rubber latex.

 

SIZES COMMERCIAL BOX TRANSPORT BOX WEIGHT LARGE ALT COMP BAR CODE
PP 100 units 1.000 units 5,3 0,23 0,23 0,33 7898949 349020
P 100 units 1.000 units 5,9 0,23 0,23 0,33 7898949 349037
M 100 units 1.000 units 6,2 0,23 0,23 0,33 7898949 349044
G 100 units 1.000 units 7,1 0,23 0,23 0,33 7898949 349051
SIZE WIDTH (mm) LENGTH (mm) SMOOTH AREA THICKNESS (MM) CENTER APPROXIMATE OF PALMA AREA LISA
PP ≤ 80 220 ≥ 0,08 ≤ 2,00
P 84 ± 3 mm 220 ≥ 0,08 ≤ 2,00
M 94 ± 3 mm 230 ≥ 0,08 ≤ 2,00
G 105 ± 3 mm 230 ≥ 0,08 ≤ 2,00

For correct use of the product, a brief asepsis must first be carried out with hand washing and subsequent drying of the same so that the gloves are then put on.

  • Contains natural latex;
  • There are isolated cases of allergic reactions to latex;
  • If there is skin irritation, discontinue the use of the material and seek medical advice;
  • Do not use if the packaging is broken;
  • Single use product – Never reuse the glove;
  • Non-sterile product;
  • Note the size of the glove before use to prevent it from tearing;
  • Store in a cool, dry place at room temperature.
  • Only for minimal risks.
  • Dexterity level 5.
  • This product has not been tested against biological agents.

This product must not be used when handling aggressive agents, chemicals/acids, hot liquids and in the presence of fire.

CAUSED PROBLEMS AND CLARIFICATIONS ABOUT THE PRODUCT

  • Perceived defect
  • Reality in most cases
  • Allergy I do not use
  • Hypersensitivity to latex proteins (1% to 2% of the population or misuse of degerming agents, lubricants or detergents).
  • Glove tearing when putting on
  • Use of inappropriate size, use of sharp or perforating objects when putting on, misuse of the hem (tensioning in an improper position)
  • Yellowing or reddening of the glove
  • Undue exposure to heat or light, contact with metals or in users with a high level of uric acid or presence of acid loads on their hands.

Classification: The TOP NUGARD procedure gloves comply with Ordinances 332 and 451 of INMETRO, ASTM D-3578-01, RDC 55/2011 Glove for non-surgical procedure, ABNT NBR ISO 11193-1 strong> Medical Examination Gloves for Single Use, Part 1: Specification for Gloves produced from rubber latex or rubber solution and NR6 from the MINISTRY OF LABOR.

Technical Name: Latex Glove with Powder for Non-Surgical Procedure – TOP NUGARD Brand

Trade name: Latex Glove – for general non-medical use

Certificate of Approval – CA :45.772

Made in Malaysia